    https://tourlomousis.pages.cba.mit.edu/cvd-electrospinning 
    
    
    ## Challenge
    
    
    ## Links for Srugical Masks, N95, Respirators etc
    - https://www.fda.gov/medical-devices/personal-protective-equipment-infection-control/n95-respirators-and-surgical-masks-face-masks
    
    
    Filippos Tourlomousis's avatar
    Filippos Tourlomousis committed
    ## Electrospinning Apparatus
    ### System Components & Process Parameters
    - Syringe Pump
        - vol. flow rate: 0.1 - 2 mL/h
    - Emitter (Hypodermic Needle)
        - Gauge: 27G / 21G
        - Preferable flat tip
    - Syringe
        - 5 mL/ 3 mL plastic
        - Luer lock (Do not use needle with slip-on design)
    - DC Voltage Supply
        - Voltage: 0 to 30 kV
        - Current: 0.5 mA to 1.5 mA
        - Note: Request for output cable.Ensure there is an earth terminal on the instrument
    - Emitter Tip to Collector Distance
        - 0 - 12 cm 
         
    ### Syringe Pump